| Sign In | Join Free | My futurenowinc.com | 
              
  | 
      
| Categories | Temperature Indicator Transmitter | 
|---|---|
| Brand Name: | Star merter | 
| Model Number: | CWDZ15CY | 
| Place of Origin: | China | 
| MOQ: | 1PC | 
| Price: | Negotiation | 
| Payment Terms: | T/T | 
| Supply Ability: | 30000 Piece/Month | 
| Range: | -50~300°C (see range parameter selection table for details) | 
| Output: | 4~20mA, 4~20mA HART, RS485, Pt100 (1/3B level) | 
| Power supply: | 9~32VDC, 13~32VDC, 15~32VDC, 15~24VDC | 
| Accuracy: | 0.25%FS, 0.5%FS | 
| Name: | Universal Temperature Transmitter | 
| Company Info. | 
| Star Sensor Manufacturing Co., Ltd | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
CWDZ15CY Universal Temperature Transmitter Measuring Range -50~300°C Widely Used In Various Industrial Fields
CWDZ15CY general-purpose temperature transmitters are well-designed and ideally suited for general purpose industries. It has a variety of explosion-proof function options, intrinsically safe, dust intrinsically safe, flameproof, explosion-proof dust, and can also choose HART protocol communication, cost-effective.
| Basic parameters | |
| Measuring medium | Liquids or gases, etc. (compatible with contact materials) | 
| Measuring range | -50~300°C (see range parameter selection table for details) | 
| Response time | Protection tube φ6mm≈18s, casing φ10mm≈36s (in line with IEC60751, 0.4m/s water flow, 10°C step) | 
| Measuring cell | 1*Pt100 (1/3B grade) | 
| Stable performance | ±0.1% FS/year | 
| Explosion-proof type | Flameproof Ex d II. C T6 Gb Intrinsically safe Ex ia II.C T6 Ga (current output only) Dust intrinsically safe Ex ia IIIC T85°CDa (current output only) Note: Intrinsically safe must be powered by a safety barrier or intrinsically safe power supply Switching time: 400ms  | 
| Ingress protection | IP66 Note: The above protection level refers to the level achieved when the electrical connection is complete  | 
| Accuracy class | 0.25%FS, 0.5%FS Meter Accuracy 0.5%FS (LCD with backlight)  | 
| Resolution | Analog output 0.02%FS, digital output 0.1°C | 
| Output power | |
| Output signal | 4~20mA,RS485,4~20mA HEART | 
| Supply voltage | 9~32VDC,13~32VDC,15~32VDC,15~24VDC | 
| Maximum power | |
| 4~20mA Yes/No Display RS485 Yes Display 4~20mA HART Yes/No Display  | ≤0.02Us(W) | 
| RS485 is not displayed | ≤0.015Us(W) | 
| Load characteristics | |
| Voltage type | ≥10kΩ | 
| Current type | No display load ≤{(Us-7.5)÷0.02}Ω With display load ≤{(Us-12)÷0.02}Ω (Us=supply voltage)  | 
| HART current type | Load ≤{(Us-12)÷0.02}Ω (Us=Supply Voltage) | 
| Environmental conditions | |
| Ambient temperature | -40~85℃ | 
| Ambient humidity | 0%~95%RH (no condensation, no condensation) | 
| Electrical protection | |
| Short-circuit protection | perpetual | 
| Reverse polarity protection | No damage, but no work | 
| Insulation resistance | ≥100MΩ,500VDC | 
| Dielectric strength | 500VAC | 
| Output limits | |
| 4-20mA | The output is 2.5mA min. 26mA max | 
| RS485 | Output minimum: 0, output max. 3500/7000 | 
| 4-20mA HART | The output is 3.8mA and the output is 22mA | 
| Overall material | |
| Protective tube material | 304 stainless steel (in contact with the medium to be measured) | 
| Process connections | 304 stainless steel (in contact with the medium to be measured) | 
| enclosure | Die-cast aluminum | 
| Display window | ≈6mm explosion-proof glass | 
| Mechanical stability | |
| Seismic performance | 10g(20… 2000Hz) in accordance with the IEC60068-2-6 standard | 
| Impact resistance | 500g/ms meets IEC60068-2-27 standard | 
                                 
                             |