50/60HZ Rated Frequency Low Voltage Current Transformer with 1A Rated Secondary Current
|
...Sensor for Low Voltage is a reliable and accurate solution for monitoring electrical currents. It features a sturdy construction that adopts high-quality PC material, ensuring durability and long-lasting performance. With rated secondary currents of 5A and...
Shenzhen Chuangyin Co., Ltd.
|
5P20 50/1A Ratio Electronic Current Transformer Protection Relay Device
|
... transformer, or ZSCT, detects the zero-sequence current, and it could work together with protection relays or signaling devices so as to monitor and protect power distribution systems. LZCG530-10 Straight-Through zero sequence Current Transformer is...
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
|
DC24V AC220V 20 Lines Pulse Signal Controller 1A Rated output current
|
DC24V AC220V 20 Lines Pulse Signal Controller 1A Rated output current Pulse Controller Description: Electronic Controller for Clean Air Systems The Pulse Controller is developed exclusively to control the cleaning of dust collector ......
Ningbo Brando Hardware Co., Ltd
|
Ring Type Low Voltage 400/5A Current Transformer With Ring Core Current
|
...Current Transformer With Ring Core Current CYR current transformer adopts high quanlity PC materials,full-enclosed construction,round hole can pass busbar,be used for controlling,protection,measuring functions. P1,P2 primary terminals,S1,S2 secondary terminals. P1&S1 same as P2,S2 (Subtractive polarity). 1. Rated primary current 5-3000A rated secondary current 5A,1A 2. Rated voltage(KV) AC 660V 3. Rated......
Yueqing Yomin Electric Co., Ltd
|
LZZBJ 10kv Epoxy Resin CT Current Transformer high voltage
|
... Other technical parameter pls see as follow: Rated current ratio (A) Accuracy classes combination Rated output (VA) FS ALF Rated short-time thermal current (kA/S) Rated dynamic current ( kA) Measuring Protective 0.2(S) 0.5 10P 10-200/5 0.2(S)/0.2(S)...
Xi'an Xigao Electricenergy Group Co., Ltd.
|
ISO9001 Split Core Current Transformer 600a Split Core Ct AKH-0.66/K-Φ Series
|
...: FS<5 ● Maximum system voltage: 720V AC ● Test voltage: 3kV AC(1min) ● Rated frequency: 50/60Hz ● Rated short-time thermal current: Ith=40~60In ● Rated dynamic current: Idyn=2.5Ith ● Rated secondary current: X/5A (X/1A upon request) ●...
Jiangsu Acrel Electrical Manufacturing Co., LTD.
|
input 100a 150a 200a 250a 300a output 1a or 5a split core current transformer
|
..., 30VA Accuracy 0.5, 1.0, 3.0 Class Rated Short-time thermal current (Ith) 20In Rated Dynamic current (Idyn) 2.5Ith Case Material UL flame retardant rating 94-V0 Highest Voltage for Equipment Um (rms) 720 Vac Rated Power-Frequency Withstand Voltage(rms) 3...
Tianjin Grewin Technology Co., Ltd
|
LZZBJ6-10Q Current Transformer Indoor Single-Phase epoxy resin casting type CT
|
... resin casting type CT Technical data The current transformers are in accordance with GB20840.2 and IEC61869-2 standards Rated insulation level: 12/42/75kV Rated frequency: 50Hz or 60Hz Rated secondary current: 5A or 1A Ambient temperature: -5 ℃~+ 40 ℃...
YUEQING RENHE ELECTRIC CO., LTD.
|
Cast Resin Current Transformer Low Voltage 5A For Ct Operated Meter , LMZ1-0.5
|
...current transformer low voltage 5A for ct operated meter Production Description: LV indoor current transformer LMZ1-0.5 epoxy cast resin type . Indoor type current ratio:5-300/5A rated voltage :0.5kv or below 1).accuracy class: 0.2 , 0.5 , 1 , 3 2).buden :5VA----50VA 3).50/60Hz 4).standard :IEC . 5).ISO Certificate Specification: 1.Primary current 1~1000A 2.Secondary current 1A......
YUEQING YOMIN ELECTRIC CO., LTD
|
0.2 Class 2000A Outdoor Split Core Current Transformer For Online Testing
|
...-2000A Jaw size 80mm×30mm External size 126mm×110mm×49mm Load capacity max 1VA (secondary 1A ), 5VA(Secondary 5A) Installation Bracket Output terminal output Features Outdoor Split-core Current Transformer Application - Utility pole probe monitoring &...
Zhengzhou Great Electric Co.,Ltd.
|
