5.3MPa FM200 Fire Suppression System 5.3MPa Fm200 Server Room 950kg/M3
|
High-Quality Fm200 Fire Suppression System Without Pollution for Museum 1. Multiple management in the control of the whole system 2. Agent quantity for biggest zone is enough to protect all zones through selector valves 3. Direct target to expensive ......
Guangdong Air Giant Fire Equipment Co.,Ltd.
|
R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H
|
... if too many electronic devices are placed in the computer room of a data center, it will cause local heat accumulation and fail to effectively dissipate heat. Furthermore, the life of the electronic equipment is lost, and even ......
Hefei Coolnet power Co., ltd
|
Dependable FM200 Gas Suppression System With ≤950kg/M3 Filling Density Extinguishing
|
... is reliable and fast-acting for archive rooms, generator rooms, power distribution rooms and machine rooms. It utilizes a gas fire suppression system to quickly suppress a fire, providing total flooding of the hazard with a non-toxic, non-corrosive,...
Guangzhou Xingjin Fire Equipment Co.,Ltd.
|
Server Room FM 200 Fire Suppression System Gas Automatic 180L HFC 227ea
|
... to defend critical server rooms and IT infrastructure from fire threats. Powered by HFC-227ea gas, this system detects and extinguishes fires in under 8-10 seconds—eliminating risks of data ......
Guangzhou Xinlin Fire Fighting Equipment Co., Ltd.
|
2.5MPa Clean Agent FM200 Cabinet System For Telecom Server Rooms
|
... automatic fire fighting system, which no damage to the protected items, leaving no residue after the fire, completely without interrupting the daily work of the protected area. Now the FM200 gas system be widely used in electrical room, data room,...
Guangzhou Xinlin Fire Fighting Equipment Co., Ltd.
|
Server Room HFC-227ea Automatic Fire Extinguisher System
|
fm-200 fire extinguishing systems qmq4.2/100n Specification Technical parameter Working pressure 4.2Mpa Type Fm200 direct type Max working pressure 5.2Mpa model QMQ4.2/100N Working temperature 0-50℃ Density of unit volume ≤950kg/m³ Max length of detecting ......
Guangdong Dingya Fire Equipment Co.,Ltd
|
Plastic PBT 94V0 0.177 M3/Min Server Room Cooling Fan
|
CHB4005CS 40x40x7.0 mm 0.114-0.177 m3/min Material Frame: Plastic PBT 94V0 Impellen Plastic PBT 94V0 Lead Wire: AWG26 "+" Red "-" Black Standard UL 1007 Option: Signal output Bearing: Ball bearing or Sleeve bearing Model Rated Voltage (DCV) Operating ......
Cheng Home Electronics Co.,Ltd
|
Frame Type Precision Air Conditioner Single Phase 3.5KW - 12.5KW For Server Room
|
Frame Type Precision Air Conditioner CDA Series 3.5-12.5KW CDArack air-conditioner model CDA0004 CDA0005 CDA0008 CDA0013 number,phase 1.5 ,single 2,single 3,single 5,single performance parameters Refrigerating capacity(kW) 3.5 5 7.5 12.5 Sensible cooling ......
Shenzhen Liruisi Electronics Co., Ltd.
|
83db 6 Ton Ac Unit Rooftop Air Conditioner 20000m3/H
|
...conditioning unit server room air conditioner VENTECH(Vcare) Rooftop air conditioning unit Central air conditioner Cooling,Heat pump, Electrical heating Parameter Cooling capacity Heating capacity Auxillary electrical heating capacity Air flow (m3/h) ESP (......
YINGDE VENTECH AIR CONDITIONING CO.,LTD
|
