-1500MV Digital ORP Electrodes Orbisint CPS12D-7PA21 Non contact Memosens
|
...ORP Electrodes Orbisint CPS12D Features and specifications ORP / Redox Potential Measuring principle ORP electrode Applications Standard applications in the process and environmental fields. Long-term monitoring of static stabilization processes. Features Non-contact Memosens digital technology. Robust, heavy dust applications, high pressure type. Measuring range -1500... +1500 mV Measuring principle - compact gel electrode...
GREAT SYSTEM INDUSTRY CO. LTD
|
CPS12D-7PA21 Digital ORP Electrodes Orbisint CPS12D -1500 mV...1500 mV, -15...135oC, 0,8...17 bar (abs)
|
...ORP Electrodes Orbisint CPS12D Features and specifications ORP / Redox Potential Measuring principle ORP electrode Applications Standard applications in the process and environmental fields. Long-term monitoring of static stabilization processes. Features Non-contact Memosens digital technology. Robust, heavy dust applications, high pressure type. Measuring range -1500... +1500 mV Measuring principle - compact gel electrode...
GREAT SYSTEM INDUSTRY CO. LTD
|
NTC10K 2000mV PH ORP Sensor ORP Electrode With PPS Plastic Shell
|
... high temperature, resist corrosion. The ORP range is ±2000mV. The pressure range of the ORP electrode is 0~4bar. A high-precision NTC10K temperature resistor is installed inside the ORP electrode to detect the solution temperature simultaneously. The...
Suzhou Delfino Environmental Technology Co., Ltd.
|
PP Material Laboratory ORP Electrode ORP Probe With 10m Cable Length
|
...ORP Electrode ORP Sensor >>Technical Parameter ORP Range: ±1000mV Temperature Range: 0-80℃ Pressure Resistance: 0-0.3MPa Temperature Sensor: OEM Housing Material: PP (Polypropylene) Sensitive Membrane: Platinum (Pt) Connection Thread: NPT 3/4’’ Cable Length: 10m or as agreed Cable Connector: Pin, BNC, or as agreed >>Overview The core theory of pH electrode......
Nanjing Juge Environmental Technology Co., Ltd.
|
3-2774 3-2776 3-2774-HT-C Georg Fischer GF Signet 2774-2777 pH and ORP Electrodes
|
...ORP Electrodes Product Description: The GF Signet 2774-2777 pH and ORP electrodes feature a unique foul-proof DryLoc ® connector with gold-plated contacts designed specifically for use with the GF Signet 2750 and 2760 preamplifiers, sensor electronics, and connectors. These dependable and highly responsive GF Signet 2774-2777 pH and ORP electrodes......
Xiamen ZhiCheng Automation Technology Co., Ltd
|
Professional GF Signet 3-2725-60 2724-2726 PH And ORP Electrodes
|
...ORP Electrodes The Signet 2724-2726 pH and ORP Electrodes feature a patented reference electrode design and use the unique foul-proof patented DryLoc® connector. The large area PE reference junction and pathway are constructed to increase the total reference effectiveness and ensure long service life. The DryLoc® connector with corrosion-resistant gold-plated contacts......
Mengchuan Instrument Co,Ltd.
|
Platium Combined ORP Electrode Sensor
|
... in most situations. 501 ORP combined electrode Work Temperature 0-70 oC Measuring unit material Platinum Type of Electrode Single-junction vitrified electrode Reference electrolyte 3.0KCl mol/L Shell material Glass Dimension Φ12*120mm Connector BNC(Q9)...
NANBEI INSTRUMENT LIMITED
|
Wide Range Continuous Water Quality Testing Equipment 10m Cable ORP Electrode
|
...Quality Sensor ORP Sensor RS485 Output without Display ORP Electrode 1. Application Kacise ORP digital sensor uses industrial on-line electrode. The front side of electrode is flat to clean easily. With built-in temperature sensor, Kacise ORP sensor is ......
Xi'an Kacise Optronics Co.,Ltd.
|
HACH MTC101 Rugged ORP Electrode with 5m Cable for Water Quality Testing
|
... Maintenance Gel Filled ORP/RedOx Electrode, 5 m Cable Intellical MTC101 is a digital combination oxidation reduction potential (ORP/RedOx) electrode with built-in temperature sensor. MTC101 has low maintenance needs thanks to a non-refillable gel-filled ......
SC Automation Limited
|
Human Body Safe Temperature Measure Tool Non Contact Thermometer
|
Human Body Safe Temperature Measure Tool Non Contact Thermometer Battery installation: use 2 no. 7 alkaline batteries. Please note that the positive and negative electrodes of the battery cannot be installed in reverse. Technical index Normal working ......
Shenzhen Optfocus Technology Co., Ltd.
|