YOKOGAWA SC42-SP34 Conductivity Cell Sensor With Wire Conductivity Transmitter
|
...: Contacting and Inductive (Toroidal, Electrodeless). When Contacting Sensors are used, the conductivity is measured by applying an alternating electrical current to the sensor electrodes (that together make up the cell constant) immersed in a solution and...
Shenzhen Wisdomlong Technology CO.,LTD
|
Ultra Pure Water Measurement Conductivity Sensor 2 Electrode Conductivity Cell
|
Conductivity Sensor 2 Electrode Conductivity Cell For Ultra Pure Water Measurement The conductivity sensor is a 2 electrode conductivity cell electrode with the K value of 0.1. It can carry out the measurement from 0.1μS/cm to 200μS/cm. The ASCK01 conductivity sensor can be used for ultra-pure water, pure water and other water treatment applications. The temperature change has a great influence on the conductance......
Suzhou Delfino Environmental Technology Co., Ltd.
|
2M Ohm CDS Photo Conductive Cell 11mm For Light Control , Light Sensor Photocell
|
...Conductive Cell 11mm For Light Control , Light Sensor Photocell Quick Details 1)Coated with epoxy 2)Good reliability 3)Small volume High sensitivity 4)Fast response 5)Good spectrum characteristic Description CdS Photoconductive Cells is a resistor which made of semi-conductor material,and the conductance change with luminance variationg.The CdS Photoconductive cells......
Guangdong Uchi Electronics Co.,Ltd
|
Clamp-type 20μS/cm 316L NPT3/4 Conductivity TDS Sensor
|
...Conductivity TDS Sensor >>Technical Parameter Conductivity Range: 0.01~20 μS/cm Resistivity Range: 0.01~18.2 MΩ·cm Electrode Mode: 2-pole Electrode Constant: K ≈ 0.01 Junction Material: 316L Temperature: 0℃~80℃ Pressure Resistance: 0~0.6 MPa Temperature Sensor: NTC10K/NTC2.2K/PT100/PT1000 Installation Interface: Clamp-type, compatible with dedicated flow cell......
Nanjing Juge Environmental Technology Co., Ltd.
|
SC42-SP24 Yokogawa Conductivity Sensor Fast Temperature Response
|
...SC42-SP24 Conductivity Sensor Product Details: Manufacturer : Yokogawa Product No. : SC42-SP24 Product Type : Conductivity Sensor Plug-in flow sensors (SS) Stainless steel cells for 2-electrode type with cell constants 0.01 and 0.1 cm-1. These conductivity sensors......
Achievers Automation Limited
|
SC42-SP26 YOKOGAWA Conductivity Sensors OFFSET AT 25 C Temperature Element
|
... sensors are ideal for high pressure, high temperature applications such as boiler blowdown and condensate leak detection applications. Designed to be high temperature conductivity sensors, these 2-electrode sensors have 316 stainless steel construction, a...
Hontai Machinery and equipment (HK) Co. ltd
|
High Pressure High Temperature Conductivity Sensor with 316 Stainless Steel 2-Electrode Design and Pt1000 Temperature Element
|
... types can handle 16 bar at 200°C and the flanged types can handle 40 bar at 250°C. Product Selection Model Code SC42 Small Bore SX42 Large Bore Cell Constants 0.1/cm; 1.0/cm 0.1/cm; 1.0/cm 0.1/cm; 1.0/cm Ranges 0.4-2,000 µS...
Xi'an Kacise Optronics Co.,Ltd.
|
E+H CLS15D-A1A1 Digital 2-Electrode Conductivity Sensor with Stainless Steel 1.4435 Electrodes and 16 mm Diameter
|
... conductivity sensors Measuring range k=0,01: 0.04 to 20 µS/cm k=0,1: 0.10 to 200 µS/cm Measuring principle Conductive conductivity cell with polished stainless steel electrodes Design 2-electrode conductivity cell with coaxially arranged ......
Mengchuan Instrument Co,Ltd.
|
MAX250B R125P02-003 Gas Sensor Cell Oxygen Sensor For Medical
|
... sensor (conductive positive/KOH electrolyte, KE series), but is more unique chemically. Because the sensor uses a weakly acidic electrolyte, the MAX-250B oxygen sensor is used in some applications such as radiation testing. Specification Working life 8...
ShenzhenYijiajie Electronic Co., Ltd.
|
E+H Germany product CLS50D-AA1C31 Digital conductivity sensor Indumax conductivity sensor
|
...conductivity sensor Indumax conductivity sensor Description: Manufacturer : Endress+Hauser Product No. : CLS50-G6C1 Product type : Indumax CLS50Inductive Conductivity Sensor Version : G = For use in hazardous areas, ATEX II 1G Ex ia IIC T4/T6 Ga Measuring ranges : Conductivity = 2 µS/cm to 2000 mS/cm (uncompensated), Temperature = -20 to +180 °C (-4 to +350 °F) Cell......
GREAT SYSTEM INDUSTRY CO. LTD
|