45° Single Core Cable Flammability Testing Equipment GB/T 25085 0.1 L ~ 1 L / Min
|
... level flame retardant in low pressure test method standard, time standard and international automobile wire used for assessment of the performance of the cable in the combustion state, test both ends fixed and perpendicular to the three sides is a...
DONGGUAN YUYANG INSTRUMENT CO., LTD
|
UL 1581 EN 60332 UL 1581 UL 2556 Single Core Cable Single Wire Flame Test Chamber VW-1 Flame Tester FT1/FT2
|
...Single Core Cable Single Wire Flame Test Chamber VW-1 Flame Tester FT1/FT2 Flame Test Chamber Technical Description: The single wire and cable vertical burning tester is suitable for measuring the vertical burning non-invasive performance of single plastic wire, control wire, cross-linked, elevator, ship, mining cable and so on. Can also be made of high self-extinguishing low-smoke halogen-free flame......
Dongguan Zhongli Instrument Technology Co., Ltd.
|
Single Cable Vertical Flame Test Chamber , Combustion Test Equipment Standard IEC60332-1-1
|
...Flame Test Chamber of single cable combustion test machine with standard IEC60332-1-1 Feature: import time and temperature controller,digital display and box separat designed 2mm stainless steel molding by numerically control ,beautiful,durable Special used burner and clamp ,complete in accord with standard requirement Pneumatic type motor control,no need man operate Technical data: Model:5704 Execute standard:GB18380.11 Test......
Suzhou Yangyi Vouch Testing technology Co.,Ltd
|
Single Wire Line Vertical Flame Test Chamber With Gb18380.1_2001 Standard
|
Single Wire Line Vertical Flame Test Chamber With Gb18380.1_2001 Standard Test standard: In line with China's national standard GB18380.1_2001 "cable in the flame under the conditions of the combustion test Part I: single insulated or vertical cable burning test method", the equivalent use of IEC60332-1. Applicable to the determination of a single plastic line, control, cross-linked, elevators, marine, mining cables......
Guangzhou Kinte Electric Industrial Co.,Ltd
|
Fire Testing Equipment / Vertical Flame Test Chamber
|
...Flame Test Chamber Application Applies to check the section area more than 0.5mm2 of single insulation wire and cable vertical flame propagation testing. Standards According to IEC60332-1-1:2004, IEC60332-1-2:2004, IEC60332-1-3:2004, EN50265-1, EN50265-2-1 Functional characteristics The vertical burning test on single wire and cable......
SKYLINE INSTRUMENTS CO.,LTD
|
Automobiles Cable HH52016 Horizontal Flame Test Chamber
|
... flame test chamber is suitable for test and determination of low-tension cables with thin wall insulation for automobiles, keep cables under fire conditions until flaming, and self-extinguish after the flame is removed within 15s Standard: • JASO D...
Dongguan HOOHA Electrical Machinery Company Limited
|
IEC 60332 Single Insulated Cable Vertical Flammability Chamber
|
...Test for vertical flame propagation for a single insulated wire or cable - Apparatus” IEC 60332-1-2 “Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable -...
Sinuo Testing Equipment Co. , Limited
|
550W UL1581 Wire Flame Test Chamber Horizontal Burning Tester Customized
|
Product Description -The UL1581 Wire and Cable Burning Test Machine is a specialized equipment used to assess the flammability characteristics of wires and cables. This machine is designed to perform the burning test as per the UL1581 standard, which is a ......
Guangdong Guangce Instrument Technology Co., Ltd
|
Automobiles Cable Horizontal Flame Test Chamber HH52016 / Electrical Circuit Testing Equipment
|
...wall insulation for automobiles, keep cables under fire conditions until flaming, and self-extinguish after the flame is removed within 15s Standard: • JASO D 618-1994 Low-tension cables with thin wall insulation for automobiles Technical parameters: •...
Dongguan HOOHA Electrical Equipment Company Limited
|
VW-1 Vertical Wire Fire Rating Flame Test Chamber with PLC Touch Screen
|
... near by of cable or flexible wire when it caught fire.The whole test is carried out in a sealed test chamber with a volume of 4.54m³. Main advantages 1, The vertical flame test chamber is electrolytic plate electrostatic spraying, elegant appearance,...
Advanced Instruments Co.,Limited
|