UL507 Fig 8.2 Test Probe For Fan Impellers HT-U09
|
... and other moving parts of stationary fans and fans intended to be permanently connected electrically. Test sample:Fan air intake. Feature:Nylon handle + probe, it is manufactured according to the standard figure. Parameters: Picture for reference:...
shanghai kerang technology co ltd
|
UL507 Fig 9.2 Articulate Probe With Web Stop Test Finger Probe For Accessibility Of Live Parts
|
UL507 Fig 9.2 Articulate Probe With Web Stop Test Finger Probe for Accessibility of Live Parts Description in UL507 Clause 9.1~9.3: 9 Accessibility of Live Parts 9.1 General 9.1.1 To reduce the risk of unintentional contact that involves a risk of electric......
Guangzhou HongCe Equipment Co., Ltd.
|
UL507 Fig 9.2 Stainless Steel Straight Unjoint Enclosure Protection Test Probe
|
UL507 Fig 9.2 Stainless Steel Straight Unjoint Enclosure Protection Test Probe Product overview: The Joint Test Probe of Figure meets the standard requirements of UL507 Fig 9.2 (PA100A), IEC 62368-1:2018 clause 4.8, 5.3.2, 8.5.4.3, V.1.2 and figure V.1, etc., UL474 Fig 5.1, UL982 Fig 7.1, UL1017 Fig 2, UL1062 Fig1.2, UL1278Fig 8.3, UL1310 Fig 16.2, UL6500 Fig14, UL60065 Fig14 and UL60950 Fig NAF.1. Technical Parameters: Probe......
Sinuo Testing Equipment Co. , Limited
|
UL1278 / UL1026 / UL507 Figure 8.2 S2140A Unjointed Rigid Finger Test Probe
|
...UL507 Figure 8.2 S2140A Unjointed Rigid Finger Test Probe for Fan Impellers and other Moving Parts Technical parameters: 1. Straight Finger Diameter: 25.4mm(1 inch) 2. Straight Finger Total Length: 101.6mm(4 inch) 3. Head Radius: R 12.7mm(1/42 inch) 5. Tail Diameter: 31.75mm(1-1/4 inch) 6. According to: UL507(S2140A)Fig.8.2 Appliance: S2140A Test Probe ,(UL Test......
HK LEE HING INDUSTRY CO., LIMITED
|
KingPo UL Test Finger , Ul Finger Probe With UL153 / UL507 / UL1026 / UL1082
|
... of UL474 Fig 5.1, UL507 Fig 9.2(PA100A), UL982 Fig 7.1, UL1017 Fig 2, UL1062 Fig1.2, UL1278Fig 8.3, UL1310 Fig 16.2, UL6500 Fig14, UL60065 Fig14 and UL60950 Fig NAF.1. Palm simulator and restricted joint movement simulates human finger movement. It is...
KingPo Technology Development Limited
|
UL Standard 234mm Articulated Probe
|
...,UL1278,UL1062,UL1310,UL474,UL60065 The UL accessibility probe is also called UL articulated probe or jointed test finger probe. It conforms to many standard requirement of UL474 Fig 5.1, UL507 Fig 9.2(PA100A), UL982 Fig 7.1, UL1017 Fig 2, UL1062 Fig1.2,...
Guangzhou Shice Equipment Co., Ltd.
|
UL1278 Fig 8.1(PA130A) UL Probe For Uninsulated Live Parts
|
...probe conforms to standard requirement of UL507-2006(PA135A)Fig 9.1, UL749 Fig 1, UL982 Fig 58.6 and UL1278 Fig 8.1(PA130A). It is used for the performance of the electrical equipment enclosure preventing electric shock. Hot Tags: ul probe for uninsulated live parts, China, manufacturers, suppliers, factory, custom, wholesale, UL1278 Fig 10.1 Test Probe......
Dongguan Kingpo Technology Limited
|
Articulate Test Finger Probe With Web Stop PA100A Stainless Steel Figure
|
...Test Finger Probe Articulate Probe With Web Stop (PA100A) Stainless Steel Figure Standard: UL1278 Movable and Wall- or Ceiling-Hung Electric Room Heaters Figure 8.3; UL 2157 Electric Clothes Washing Machines and Extractors Figure 1; Other standard IEC62368Fig V1, UL474 Fig 5.1, UL507 Fig 9.2(PA100A), UL982 Fig 7.1, UL1017 Fig 2, UL1062 Fig1.2, UL1310 Fig 16.2, UL6500 Fig14, UL60065 Fig14 and UL60950 Fig......
HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
|
PG-PA145 Lab Testing Equipment UL Test Rod Probe Meet UL982 Standard Requirements
|
...Testing Equipment UL Test Rod Probe meet the requirements of UL982 Standard 1. Introduction of UL Test Rod Probe The UL test rod probe is designed according to the standard of UL982 fig. 58.6, UL1278 Fig. 8.2, UL398 fig. 8.2 (PA170B), UL507 (PA170D) and UL749 fig.2. It's used for testing enamel coated wires. 2. Application of UL Test Rod Probe: Transformers and Inductors 3. Parameter of UL test Rod Probe......
Pego Electronics (Yi Chun) Company Limited
|
