UL982 PA190 Test Probes For electrode type Heating Appliances
|
UL982 PA190 Test Probes For Electrode Type Heating Appliances UL982-2006 Figure 58.5(PA190) Test Probe For Protection Test Of Portable Electrode-Type Heating Appliances Product details: It conforms to the standard of UL499 Fig 6.4 and UL982-2006 Fig 58.5(PA190). It is applicable for the electrical equipment. The handle is made of Nylon, and the tip is stainless steel. Standard:UL499 Fig 6.4 and UL982......
Dongguan Kingpo Technology Limited
|
UL982 Test Finger Probe For Uninsulated Live Parts Film Coated Wire Length 101.6mm Diameter 19.1
|
... an opening which does not permit entrance of a 3/4 inch-diameter (19 mm) rod is acceptable if: a) A probe as illustrated in Figure 58.6 cannot be made to touch any uninsulated live part or moving part capable of causing injury when inserted through the...
Guangzhou HongCe Equipment Co., Ltd.
|
UL Standard / IEC 62368-1 Figure V.1 heat-treated steel Jointed Test Probe Simulating Human Finger Movement
|
...Test Probe Simulating Human Finger Movement Application: This jointed Test Finger Probe is strictly designed and manufactured according to UL507,UL982,UL1278,UL1062,UL1310,UL474,UL60065 . Palm simulator and restricted joint movement simulates human finger movement. Made of all nylon. Bell-Core accessory available.This ul jointed test finger probe......
KingPo Technology Development Limited
|
IEC62368-1 Clause 4.8 Figure V.1 Jointed Test Probe For Equipment
|
... requirements of IEC62368-1 Clause 4.8,5.3.2, 8.5.4.3 Figure V.1, UL474 Fig 5.1, UL507 Fig 9.2(PA100A), UL982 Fig 7.1, UL1017 Fig 2, UL1062 Fig1.2, UL1278Fig 8.3, UL1310 Fig 16.2, UL6500 Fig14, UL60065 Fig14 and UL60950 Fig ......
Sinuo Testing Equipment Co. , Limited
|
5A 2.03 MM Outer Diameter GKS-003 Pitch Gold-plated Test Probe with BeCu Plunger and Brass Barrel
|
...m many manufacturers with similar constraints. When selecting a test probe receptacle, the tip choice is the most critical consideration. Detailed illustration of test probe components and construction Various test probe tip types Customization Options At...
SICHUAN WINNER SPECIAL ELECTRONIC MATERIALS CO., LTD.
|
75N force test probe,rigid test probe,safety test probe,iec test probe.access test probe
|
...test probe,rigid test probe,safety test probe,probe test Model TP11: 75N force test probe,rigid test probe,steel test probe rigid test probe is used to assess protection of persons against access to dangerous parts and to assess the mechanicalresistance of openings in the enclosure or inner separations. rigid test probe is made of high-grade steel in accordance with the standards and conforms the measures of the flexible finger probe...
ALLIED TESTING (HK) CO.,LTD.
|
1000V / 10A Multimeter Test Probes Digital Electrical Test Leads Long Service Life
|
...Test Probes And Pen-Typing Lead Probe Wire Features Probe Length: 120mm/Probe Tip Ø2mm Probe Plug: Ø4mm Cross Plug, Right angle type Probe Wire: 22AWG, red/black Length: 800mm Safety Class: EN61010-031, 1000V CAT Ⅱ, MAX 10A DESCRIPTION 10A ULTRA SOFT PROBE TEST Lead Length Probe......
Guilin Huayi Peakmeter Technology Co., Ltd.
|
IEC61032 Rigid test probe 11, IEC60529 Rigid test probe 11
|
IEC61032 Rigid test probe 11, IEC60529 Rigid test probe 11 Product Description IEC61032 Rigid test probe 11, IEC60529 Rigid test probe 11 Introduction: Bonad offers a wide range of probes to meet the most common standards including those from IEC, EN, UL, ......
HongKong Bonad Technology Limited
|
High Precision IP Testing Equipment , Test Probe B Insulating Material
|
...probe C for IP3X testing: Φ2.5 rod-length 100 Test Probe D for IP4X testing: Φ1.0 wire-length 100 Test Probe 1: 500g steel sphere Test probe 2: 15g steel sphere Test Probe A Introduction: Designed according to IEC61032 fig.1, and meet the requirements of...
Pego Electronics (Yi Chun) Company Limited
|
DC-11GHz Coaxial RF Test Probe SMA Female To MCX Test Connector Adapter
|
...test connector adapter RF coaxial test probe The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe......
Charter Leader Precision Electronic Co.,Ltd
|