PA130 Ul Finger Probe Stainless Steel Tip For Uninsulated Live Part
|
PA130 UL Accessibility Test Probe for Uninsulated Live Part Conforms to UL507 Introduction UL accessiliby test probe for uninsulated live part is designed according to UL507 figure 9.1 (PA135A) and UL1278 figure 8.1 (PA130A). The handle is made by nylon......
Pego Electronics (Yi Chun) Company Limited
|
UL507-2006 UL Articulated Finger Probe For Uninsulated Live Parts
|
UL Probe for Uninsulated Live Parts Product information: This probe conforms to standard requirement of UL507-2006(PA135A)Fig 9.1, UL749 Fig 1, UL982 Fig 58.6 and UL1278 Fig 8.1(PA130A). It is ......
Guangzhou HongCe Equipment Co., Ltd.
|
UL1278 Fig 8.1(PA130A) UL Probe For Uninsulated Live Parts
|
...probe conforms to standard requirement of UL507-2006(PA135A)Fig 9.1, UL749 Fig 1, UL982 Fig 58.6 and UL1278 Fig 8.1(PA130A). It is used for the performance of the electrical equipment enclosure preventing electric shock. Hot Tags: ul probe for uninsulated live parts, China, manufacturers, suppliers, factory, custom, wholesale, UL1278 Fig 10.1 Test Probe, Double-Layered High Low Temperature Chamber, UL...
Dongguan Kingpo Technology Limited
|
UL507-2006 UL Probe for Uninsulated Live Parts
|
... of the electrical equipment enclosure preventing electric shock. Test sample:Easily accessible enclosure live parts or mechanical parts. Feature:Nylon handle + probe, it is manufactured according to the standard figure. Parameters: Picture for reference:...
shanghai kerang technology co ltd
|
PA130A Uninsulated Live Parts Probe of UL1278 Fig 8.1
|
UL Rigid test finger 130A meets the standard requirements of UL 507&UL 1287, used for simulating fingers and appliances. It is mainly used for checking whether the live parts are touched. Mainly used for testing the no insulation live parts. Basic Introduction: 1, According to UL1278/UL1026 and UL507; 2, Applicable to the apparatus structure and shell easy access to live parts of protective performance check; 3, The probe......
HK LEE HING INDUSTRY CO., LIMITED
|
Nylon Handle UL 1278 Test Finger Probe Figure 8.1 PA130A PA140A
|
... 8.2 Probe for film-coated wire. Application: It is used for the testing of coating lines of the enamel (i.e., transformers and inductors). And for the performance of the electrical equipment enclosure ......
HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
|
UL1005 Electric Flatirons Probe Figure 7.1
|
... inserted point first, cannot be made to touch any uninsulated live part. Data to be calibrated Test Point Nominal Value (mm) Actual Value (mm) Deviation (mm) Limit (mm) Uncertainty (......
KingPo Technology Development Limited
|
UL 2594 Clause 8.2 Figure 6 Articulated Probe Nylon And Metal Material
|
...enclosure protection test of the electrical equipment. Test sample: Easily accessible enclosure live parts or mechanical parts. Feature: Nylon handle + probe, it is manufactured according to the standard figure. Technical Parameters for UL 2594 Clause 8.2...
Sinuo Testing Equipment Co. , Limited
|