Sign In | Join Free | My futurenowinc.com |
|
All 2000t ratio clamp ct transformer wholesalers & 2000t ratio clamp ct transformer manufacturers come from members. We doesn't provide 2000t ratio clamp ct transformer products or service, please contact them directly and verify their companies info carefully.
Total 39 products from 2000t ratio clamp ct transformer Manufactures & Suppliers |
|
![]() |
Brand Name:GFUVE Model Number:LZCK-55 Place of Origin:BEIJING CHINA ...-rs485-rj45-with-pc-software.htmlhttp://www.zerosequencecurrenttransformer.com/sale-10367681-medium-voltage-split-core-current-transformer-10kv-clamp-on-current-transformer.html LZCK-55 IP68 200/5A High magnetic core Clamp Outdoor Split Core CT for |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:GDZX Model Number:ZX-SBC Place of Origin:China ... of traditional transformer ratio bridge test. The screen adopts large screen high-resolution LCD, and the power supply adopts lithium battery, which is convenient for ... |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
![]() |
Place of Origin:China Brand Name:ERFA Model Number:CT022 Key Specifications/Special Features: Specification notes Single-phase current test/quality warranty Clamp-on current transformer Current range 100mA to 6kA Mainly using for: Clamp-on current transformer Clip on current transformer Current transformer clamp... |
ERFA Industries Group
|
![]() |
Brand Name:HEMEI Model Number:HM-CTC1535 Place of Origin:China Split Core Current Transformer Clamp On Type The HM-CTC1535 is a high performance AC clamp on Current transformer with excellent transformation and low phase shift. The high quality magnetic core and uniform windings provide for accurate measurements up ... |
Hefei Hemei Electronics Technology Co., Ltd
Anhui |
![]() |
Brand Name:Shinhom Model Number:SCTK Series Place of Origin:China ...core design permits non-contact current measurements through magnetic field induction without disconnecting cables circuits for CT installation. This method permits a safer, easier and portable current measurement. Features: Test range: 5 to 200A AC input, |
Shaanxi Shinhom Enterprise Co.,Ltd
Shaanxi |
![]() |
Brand Name:GENY Model Number:HN-2K01B2 Place of Origin:China Automatic Portable CT On-Site Transformer Test Equipment for Testing of CT’s Radio/Angle Error in Accuracy Class 0.05 Specifications: Current Mutual-inductor On-site Calibration Device The product is mainly used to test one grade to 0.2S grade field ... |
Guangzhou GENY Electric Co., Ltd
|
![]() |
Brand Name:Twinkle Industrial Model Number:TIACP-17 Place of Origin:China ... Product Description: CT clamp, also known as a current transformer clamp, is a device used to measure the electrical current flowing through a conductor without the need to disconnect the conductor. It is a non-invasive method of measuring current and |
Henan Twinkle Industrial Co., Ltd
Henan |
![]() |
Brand Name:HAOMAI Model Number:CTP-120PA Place of Origin:China ...Ratio CT Analyzer Model: CTP-120PA The Multi-Ratio CT Analyzer CTP-120PA is all-in-one testing system for protection and metering CTs according to IEEE and IEC standards. It allows all types of single and multi-ratio current transformers to be tested on-site in power system grids. Manufacturer of CTs, transformers or GIS use the CT Analyzer in their production facilities and test or development labs. The Multi-Ratio CT... |
HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD
|
![]() |
Brand Name:LAB TECH Model Number:CPT-III Place of Origin:China ...CT PT Tester -- Model: CPT-I Introduction: CPT-I CT PT Tester is a special instrument for testing characteristic of CT and PT. CPT-I CT PT Tester can finish CT/PT transformation ratio test, CT/PT polarity test, volt-ampere feature curve drawing and CT error drawing. CPT-I CT PT Tester has large output, high precision,stable performance and automatic testing. Features: CT/PT transformation ratio test CT /PT polarity test CT... |
Delta Technology (Chongqing) Co., Ltd.
Chongqing |
![]() |
Brand Name:AI Model Number:CPT-I Place of Origin:China ...CT VT Test Equipment Test for current transformer: Excitation curve and parameters test Turns ratio test Ratio and phase error test Polarity mark check Winding resistance measurement Secondary loop burden measurement Error line curve test for protection CT Transient CT parameters test CT nameplate guess Saturation hysteresis loop curve measurement Tests for Potencial Transformer: Turns ratio test Ratio... |
Advanced Instruments Co.,Limited
Hunan |
![]() |
Brand Name:XZH TEST Model Number:XHTX201D Place of Origin:Xi'an, Shaanxi, China ... Transformer CT/PT Analyzer Single Phase Excitation Ratio Testing Product Description XHTX201D CT/PT ANALYZER is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity... |
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
|
![]() |
Brand Name:RISING Model Number:RSCT-201 Place of Origin:China ... for online measurement of primary current and secondary current size, conversion ratio, phase difference and polarity judgment of current transformers and transformers below 35kV.The product is composed of primary current clamp (high voltage detector), |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Place of Origin:China Brand Name:SUCHEN Model Number:DX-20 ...necessary to disconnect the measuring instrument from the transformer without damage to the CT, or for easier termination to ground of the CT Features 1) Safe, easy to install, portable 2) Wide inner window, allowing clamping of big cables or bus-bars 3) |
YUEQING RENHE ELECTRIC CO., LTD.
|
![]() |
Place of Origin:Wuhan,Hubei,China Brand Name:Huaying CT PT Analyzer HYVA-404 Tests for Current Transformer: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Transient CT parameters test 9 CT nameplate guess 10 Saturation hysteresis loop curve measurement Tests for Voltage Transformer: 1 Turns ratio test 2 Ratio... |
Wuhan Huaying Electric Power Tech & Science Co.,ltd
Hubei |
![]() |
Brand Name:IVY Model Number:200A-Open Core CT Place of Origin:Zhejiang ... & Control Unit 2.Technical Parameters: Main Parameter Parameters KCT-26-12 Rated primary Current 6(200)A/2mA Ratio 3000:1 Voltage Insulation AC >3000V Accuracy (ratio error ) ±0.5% Accuracy (phase error ) 45’ Coil Resistance ≤250Ω |
IVY METERING CO.,LTD
Shanghai |
![]() |
Brand Name:Huaying Model Number:Huaying Series Place of Origin:Wuhan Hubei China ...CT PT Analyzer HYVA-404 2. Equipment Description: 1)Excitation curve and parameters test 2)Turns ratio test 3)Ratio and phase error test 4)Polarity mark check 5)Winding resistance measurement 6)Secondary loop burden measurement 7)Error line curve test for protection CT 8)Transient CT parameters test 9)CT nameplate guess 10) Saturation hysteresis loop curve measurement Tests for Voltage Transformer: 1) Turns ratio test 2) Ratio |
Wuhan Huaying Electric Power Tech & Science Co.,ltd
Hubei |
![]() |
Brand Name:Metrum Model Number:HES-10 Place of Origin:China ...CT & PT Accuracy Testing System System Configuration HES-10 CT&PT Test Bench HES-1C Digital Transformer Tester FY49 Current Transformer Burden (5A/1A optional) HLS-30G2 Standard Current Transformer ( with Current Source) FY95 Voltage Transformer Burden (100V,100/√3V or other ratio requirements are available) HJS-35G2 Standard Voltage Transformer ( with Voltage Source) Current Transformer Primary Testing Cable CT... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
![]() |
Brand Name:Yomin Model Number:YM-SCT-T24 Place of Origin:Wenzhou, Zhejiang ... manageable values. They're connected with the Panel Meter or Relay and they can help to measure the current or protect the equipments. Low voltage current transformers are manufactured as of two types for measuring CT. Safety : Current transformers are |
YUEQING YOMIN ELECTRIC CO., LTD
Zhejiang |