| Sign In | Join Free | My futurenowinc.com |
|
All 3 phase motor starter with overload protection wholesalers & 3 phase motor starter with overload protection manufacturers come from members. We doesn't provide 3 phase motor starter with overload protection products or service, please contact them directly and verify their companies info carefully.
| Total 15 products from 3 phase motor starter with overload protection Manufactures & Suppliers |
|
|
|
Brand Name:YOKG Model Number:SE1-09~18 Place of Origin:China SE1-D18 3 Phase Motor Standard Power Electric Magnetic Starter Relay Contactor Application: SE1 series magnetic starter is mainly used in the circuit of AC 50 HZ or 60 HZ, rated insulation of 440V, and the rated current up to 95A, apply to start the ... |
YueQing ZEYI Electrical Co., Ltd.
Zhejiang |
|
|
Brand Name:WZSTEC , SONTUOEC Model Number:SE1-N Place of Origin:China Magnetic Starter Se1-N Series ( LE1-N ) From 9-95A for Motor Protection (DOL) A magnetic starter is an electromagnetically operated switch which provides a safe method for starting an electric motor with a large load. Magnetic starters also provide under-... |
WENZHOU SANTUO ELECTRICAL CO.,LTD.
Zhejiang |
|
|
Brand Name:EMHEATER Model Number:EM-GB3-055 Place of Origin:CHINA 55kw 3phase 400V built in bypass soft starter for pump EM Motor Soft Starter This soft starter is an advanced digital soft starter solution for motors from 11kW to 600kW. Provides a complete range of motor and system protection features to ensure reliable ... |
CHINA EM TECHNOLOGY LIMITED
|
|
|
Brand Name:KRIPAL Model Number:UKW1 series Place of Origin:China ... component, while also providing power-cutoff, under-voltage, and overload protection. Description: UKW1 series magnetic motor starter are suitable for 50Hz or 60Hz, rated voltage up to 660V, current up to 95A circuit. In order to protect motor starting, |
Zhejiang KRIPAL Electric Co., Ltd.
Zhejiang |
|
|
Brand Name:VEIKONG Model Number:VKS6000 Place of Origin:China 11kw 15hp 3 phase 220v 380v 11kw soft starter ac frequency inverter Key Feature 1, Six group parameters convenient in one soft starter to different power motors load. 2, Dynamic fault recording function and Inspecting motor feedback to realize closed loop ... |
Shenzhen LuoX Electric Co., Ltd.
Beijing |
|
|
Brand Name:Winston/OEM Model Number:3VU1300 Place of Origin:China,Zhejiang ...Overload Protection 63A 3VU1300 Plastic Electric Breaker MCCB Description The product is suitable to be used in circuit of rated voltage up to AC 660V 50/60Hz, rated current from 0.1A to 63A. It is applicable for protection of overload & short circuit of 3 phase squirrel-cage motors. It also can be used as direct starter to start the motor... |
YUEQING WINSTON ELECTRIC CO.,LTD.
Zhejiang |
|
|
Brand Name:VEIKONG Model Number:VKS8000 Place of Origin:China ...Phase Intelligent Bypass Soft Starter Or Pumps And Motors Product Feature Customization protection • Motor overload • Start timeout • Undercurrent • Current imbalance • Input phase loss • Output phase loss • Soft starter overheated • Motor overheated • Phase... |
Shenzhen Veikong Electric Co., Ltd.
|
|
|
Brand Name:Acrel Model Number:ARD2F Place of Origin:China ..., grounding/leakage, and locked-rotor. The products are divided into two categories: ARD2 simple series and ARD3** series. The ARD protector can form a motor control protection unit with electrical components such as contactors, motor starters, etc. |
Jiangsu Acrel Electrical Manufacturing Co., LTD.
Jiangsu |
|
|
Brand Name:Allen Bradley Model Number:193-ECM-DNT Place of Origin:USA ...Overload Relay Specification Product Description The 193-ECM-DNT is an Electronic Overload Relay manufactured by Allen-Bradley, designed to protect motors from overloads, short circuits, and phase imbalances in industrial applications. It provides reliable motor protection in conjunction with circuit breakers and motor starters... |
MOORE AUTOMATION LIMITED
Fujian |
|
|
Model Number:3RV1331 3RV1341 3RV1342 Place of Origin:Germany SIRIUS 3RV1 Motor Control Circuit Breaker 3RV1011 To 3RV1042 Motor Protector Application 3RV series motor protection circuit breakers are mainly used for the overload,short-circuit and phase-failure protection for motors in the circuit of AC 50/60Hz,rated ... |
Yueqing Richuang Automation Equipment Co.,Ltd
Zhejiang |
|
|
Brand Name:Schneide Model Number:ATS01N222QN Place of Origin:French Key Features Cost-Efficient Design: Built-in bypass contactor reduces external component requirements. Compact footprint saves panel space (45 mm width). Advanced Protection: Motor thermal protection, phase imbalance detection, and overload alerts. Coating... |
Xiamen Online Union Technology Co., Ltd
|
|
|
Brand Name:PLC Model Number:150-C85NBD Place of Origin:USA ... Normal Product Description Our SMC™-3 Soft Starters are available with a current range from 3...480 A. They feature compact, true three-phase control in a cost-effective package. They include overload protection, integral bypass, and motor and system |
Wuhan Sean Automation Equipment Co.,Ltd
|
|
|
Brand Name:Renle Model Number:SSD1-300-E Place of Origin:Shanghai ... protection functions such as overcurrent, overheating, phase failure, motor overload, etc. Bring your own standard Modbus communication protocol; Compact structural design, convenient installation and easy use; The terminals are plug-in and plug-out for |
Shenzhen Wisdomlong Technology CO.,LTD
Guangdong |
|
|
Place of Origin:China Brand Name:Shanghai People Application: JRS1 series thermal relay is suitable for using in the circuits rated voltage up to 660V, ratedcurrent 80A, AC 50/60Hz, for over-current protection of AC motor. The relay has the differential mechanism and temperature compensation and can plug... |
Shangmin Electric Group Co.,ltd
Zhejiang |