Sign In | Join Free | My futurenowinc.com |
|
All 4 20ma analog signal isolation transmitter wholesalers & 4 20ma analog signal isolation transmitter manufacturers come from members. We doesn't provide 4 20ma analog signal isolation transmitter products or service, please contact them directly and verify their companies info carefully.
Total 54 products from 4 20ma analog signal isolation transmitter Manufactures & Suppliers |
|
![]() |
Brand Name:JSD Model Number:JSD TA-1002- Place of Origin:SHENZHEN,CHINA ... is a signal conditioner with electrical insulation between input and output, it can receive a variety of analog signal from the field instrument, and transmit a standard output signal or user-specified special signal to the control room,PLC,PC or DCS. The |
Isolation transmitter|isolation amplifier|analog isolation amplifier
Guangdong |
![]() |
Brand Name:WAYJUN Model Number:DIN11 IAP-PWM Place of Origin:CN ... transmission >>Instrument signal transceiver >>Power monitoring, medical equipment isolation >>Ground interference suppression >>PLC / FA motor control signal isolation >>Pulse width measurement PWM signal to 4-20ma/0-10V isolated converters Features: & |
Shenzhen WAYJUN Industrial Automation
Guangdong |
![]() |
Place of Origin:Baoji,China Brand Name:HT SENSOR Model Number:BPHT24 ...20mA Analog Signal Flush Diaphragm Industrial Pressure Sensor For Sanitary BPHT24 Pressure Transmitter Introduction of Industrial Pressure Sensor: BPHT24 pressure transmitter utilizes the HT series flat diaphragm silicon pressure-resistance isolation oil-filled core as the signal measuring element. The signal processing circuit is located inside a stainless steel housing, converting the sensor signal into a standard output signal... |
Baoji Hengtong Electronics Co., LTD
Shaanxi |
![]() |
Brand Name:LS Model Number:LS-TET-AI Place of Origin:China Input Input current range: AC 0-10A Input voltage range: AC 0-1000V Frequency range: 40Hz-60Hz Output Output signal: 4-20mA; 0-20mA; 0-5V; 0-10V Output load resistance: RL ≤ 500Ω (when the output is a current signal) RL ≥ 10KΩ (when the output is a voltage... |
Shenzhen Qianhai Lensen Technology Co., Ltd
Guangdong |
![]() |
Brand Name:Jetacon Model Number:THS-IP Place of Origin:Guang Dong Voltage / Current Isolator will isolate DC voltage or current signals, convert them into required signals and transmit to other instrument. It can be used together with modular instrumentation and DCS, PLC and other systems, to offer signal isolation, ... |
Shenzhen Jetacon Technology Limited
Guangdong |
![]() |
Brand Name:Jetacon Model Number:THS-IP Place of Origin:Guang Dong Voltage / Current Isolator will isolate DC voltage or current signals, convert them into required signals and transmit to other instrument. It can be used together with modular instrumentation and DCS, PLC and other systems, to offer signal isolation, ... |
Jetacon Technology Limited
|
![]() |
Brand Name:Jetacon Model Number:THS-IP Place of Origin:Guang Dong Voltage / Current Isolator will isolate DC voltage or current signals, convert them into required signals and transmit to other instrument. It can be used together with modular instrumentation and DCS, PLC and other systems, to offer signal isolation, ... |
Shenzhen Jetacon Technology Ltd
|
![]() |
Brand Name:Jetacon Model Number:THS-IP Place of Origin:Guang Dong Voltage / Current Isolator will isolate DC voltage or current signals, convert them into required signals and transmit to other instrument. It can be used together with modular instrumentation and DCS, PLC and other systems, to offer signal isolation, ... |
Shenzhen Dihaola Industrial Ltd
|
![]() |
Brand Name:PR Model Number:3185A Place of Origin:The Danish application 1:1 standard current signal isolation, signal range 0(4)... 20 mA. Standard DIN rail installation. Both in terms of technology and cost, it is the choice of electrical isolation of current signals. It can effectively suppress the surge current... |
QIN XIN (HONG KONG) ELECTRONIC TECHNOLOGY CO.,LIMITED
|
![]() |
Brand Name:Yunyi Model Number:6000 Place of Origin:China ...20ma Signal Isolation Converter Description Slim Type Thermocouple Temperature 4 20ma Signal Isolation Converter The isolation converter provides isolated working power to the transmitter in the field, and detects the The current/voltage signal, after transformation, outputs an isolated current/voltage signal, realizing Three-terminal isolation... |
Xi'an Yunyi Instrument Co., Ltd
|
![]() |
Place of Origin:China Brand Name:OEM Model Number:JM-B-3B ...Transmitter Use This transmitter ia used to turn the measured vibration value to standard 4~20mA current signal output, and feeds it to PLC, DCS or DEH systems ,it is small in size, with high accuracy and easy to install. Functions 1.Mianly applying to measuring absolute vibration(i.e.bearing vibration) of rotating machinery. 2.4~20mA analog current output. 3.TDM synchronous signal... |
Hontai Machinery and equipment (HK) Co. ltd
Guangdong |
![]() |
Brand Name:SHELOK Model Number:2088 Place of Origin:China 2088 differential pressure transmitter with 4-20mA output signal Description 2088 pressure transmitter is made with oil-filled isolation membrane-specific integrated pressure sensors and instrumentation amplifier circuit, it has a high accuracy, good ... |
Xi'an Shelok Instruments Technology Co., Ltd.
|
![]() |
Brand Name:Sier Place of Origin:China ... silicon oil-filled core, 316L stainless steel isolation diaphragm and high-performance amplifier circuit. With 4-20mA, voltage, RS485 and other outputs. Current output, usually designed for conecting to the standard 4-20mA current loop widely used in |
Shaanxi Sier Electronics Co., Ltd.
Shaanxi |
![]() |
Brand Name:WNK Model Number:WNK-621 Place of Origin:Anhui, China ...signals to carry to a long distance or guard against heavy field electrical noise. The transmitter converts various input to an analog signal for direct interface with Indicators, recorders, controllers, PLC, DCS, systems can be used for a wide range of |
Hefei WNK Smart Technology Co.,Ltd
Anhui |
![]() |
Brand Name:Acrel Model Number:BM100-DI/I Place of Origin:China BM Series Signal Isolators BM100 series signal isolators can measure the electrical parameters such as current and voltage or non-electrical parameters such as temperature and resistance at high speed and accurately, and can be converted into standard ... |
Jiangsu Acrel Electrical Manufacturing Co., LTD.
Jiangsu |
![]() |
Brand Name:MC Place of Origin:China Model Number:148 148 Isolation Voltage greater than 1000V Temperature Transmitter 4-20Ma with digital signal based on HART Protocol *, *::before, *::after {box-sizing: border-box;}* {margin: 0;}html, body {height: 100%;}body {line-height: 1.5;-... |
Yueqing NengYang trading Co., Ltd.
|
![]() |
Brand Name:Yokogawa Model Number:AAI143-H53 Place of Origin:japan ...Analog Input Module 4 To 20mA, 16-Channel, Isolated Manufacturer :Yokogawa Product No. : AAI143-H53/K4A00 Product Type : Analog Input Module H : With digital communication (HART protocol) 5 : With no explosion protection 3 : With ISA Standard G3 option and temperature (-20 to 70 °C) option This module provides 16 inputs of 4 to 20 mA signal... |
Xiamen ZhiCheng Automation Technology Co., Ltd
Guangdong |
![]() |
Brand Name:WNK Model Number:WNK65 Place of Origin:Anhui, China PT100 4-20m Head Mounted Temperature Transmitter With Hart Product Description WNK 4-20m Head Mounted Temperature Transmitter Universal Input Isolation Smart Temperature Transmitter WNK65 is suitable for four types of thermal resistors including Cu50, ... |
Hefei WNK Smart Technology Co.,Ltd
Anhui |
![]() |
Brand Name:Kacise Model Number:GXPS353 Place of Origin:China GXPS353 Analog signal output 4-20mA Output Pressure Sensor for Automatic Detection System Application Compressor Floor house water supply Hydraulic control Air conditioning unit Automobile engine Automatic detection system Hydraulic unit Refrigeration ... |
Xi'an Kacise Optronics Co.,Ltd.
Shaanxi |
![]() |
Brand Name:DCL Model Number:DCL-05F/10F/20F/40F/60F/100F/160F/250F Place of Origin:WUHAN,CHINA ... 4-20mA analog signal of valve position. It can be widely used in 3-point floating control system to drive quarter turn butterfly valves, ball valves or dampers. This kind of control system can obtain continuous analog signal of valve position signal to |
Dynamic Corporation Limited
Hubei |