| Sign In | Join Free | My futurenowinc.com |
|
All annex t 6 impact test device wholesalers & annex t 6 impact test device manufacturers come from members. We doesn't provide annex t 6 impact test device products or service, please contact them directly and verify their companies info carefully.
| Total 6 products from annex t 6 impact test device Manufactures & Suppliers |
|
|
|
Brand Name:Sinuo Model Number:SN2202 Place of Origin:China ...-1: 2013 Clause 4.2.5, IEC 60065:2014 clause 12.1.4 fig.8, 12.7.3.5, IEC 60598-1 Clause 4.13.4a, etc. Application: This device is suitable for drop impact test for equipment enclosure. Test sample: Luminaries, Audio, video and similar electronic apparatus, |
Sinuo Testing Equipment Co. , Limited
Guangdong |
|
|
Impact Testing Mechanical Testing Machine Calibration Device For Spring Impact Hammer As Per Annex BBrand Name:HongCe Model Number:SH-7 Place of Origin:China ... of the pendulum <0.002J Trigger distance >30mm Balance weight 2J Copper weight 1 piece Material Stainless steel Description: This device is |
Guangzhou HongCe Equipment Co., Ltd.
Guangdong |
|
|
Brand Name:HJ Model Number:SH-7 Place of Origin:China ... device is intended to verify the impact energy of spring operated impact hammers. Test sample: Spring hammer test apparatus Principle of calibration: The principle of this calibration procedure is to compare the energy provided by a spring hammer, which |
HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Guangdong |
|
|
Brand Name:SHC Model Number:SC-IK01 Place of Origin:China Impact Testing Device Striking Element 2J 5J 10J 20J IEC60068-2-75 Parameters: Model(Energy) 2J 5J 10J 20J 50J equivalent mass(kg) 0.5 1.7 5 5 10 Dripping height(±1% mm) 400 300 200 400 500 Diameter(mm) 35 60 80 100 125 Standard: IEC60068-2-75 Annex A Application: This device is suitable for mechanical impact strength test... |
Guangzhou Shice Equipment Co., Ltd.
|
|
|
Place of Origin:China Brand Name:KeRang ...Device for Spring Impact Hammer SH-7 Parameters: Accuracy: 0.01J Repeat accuracy: ±0.01J Measurement range: 0~2J Guide groove diameter: 51mm The energy loss of the pendulum: <0.002J Trigger distance: >30mm Balance weight: 2J Copper weight 1 piece Standard: IEC 60068-2-63 Annex A, IEC 60068-2-75 Annex B Application: This device is intended to verify the impact energy of spring operated impact hammers. Test... |
shanghai kerang technology co ltd
Shanghai |
|
|
Brand Name:PEGO Electronics Model Number:PG-SHC Place of Origin:China Spring Hammer Calibration Device as per IEC60068-2-75 Annex B and figure B.1 1. Introdcution The calibration device is designed according to GB2423.44 Annex A, GB2423.55 Annex B, IEC60068-2-63 and IEC60068-2-75 standard Annex B. It’s applied to check the ... |
Pego Electronics (Yi Chun) Company Limited
Jiangxi |