| Sign In | Join Free | My futurenowinc.com |
|
All current transformer rating factor wholesalers & current transformer rating factor manufacturers come from members. We doesn't provide current transformer rating factor products or service, please contact them directly and verify their companies info carefully.
| Total 93978 products from current transformer rating factor Manufactures & Suppliers |
|
|
|
Brand Name:Chuangyin Model Number:LSZ107 8 Place of Origin:China ...Current Transformer, Three Phase Rated Secondary Current 5A,1A The three-phase CT is full-enclosed in the flame retardant plastic shells, primary bushing or cable can pass through the Inner hole, bottom has Installation Inserts for fixation. It Is simple and shortcut, Is suitable for measuring current, signal collection and protective relaying In the medium voltage power system of bushing or cable etc. Purpose Measuring current |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
|
|
Place of Origin:Tianjin Brand Name:grewin Model Number:GWTA serials ... M Ohms @ 500 Vdc Surge Withstand 5000V(1.2/50μs standard shock wave)optional Rated Load Resistance 100K Ohms Operating Temperature -25 to +55℃,-40 to +85℃optional Frequency 50 to 400 Hz ... |
Tianjin Grewin Technology Co., Ltd
Tianjin |
|
|
Brand Name:Acrel Model Number:AKH-0.66 Place of Origin:Jiangsu, China ...: FS<5 ● Maximum system voltage: 720V AC ● Test voltage: 3kV AC(1min) ● Rated frequency: 50/60Hz ● Rated short-time thermal current: Ith=40~60In ● Rated dynamic current: Idyn=2.5Ith ● Rated secondary current: X/5A (X/1A upon request) ● |
Jiangsu Acrel Electrical Manufacturing Co., LTD.
Jiangsu |
|
|
Brand Name:YOMIN Model Number:DS Place of Origin:Made in China ...Current Transformer Class 0.5 With Electric Meter FEATURE: Busbar mounting Primary current from 5A to 3000A.SPECIFICAIONS Rated Frequency 50/60Hz Rated test voltage 3kV AC. (1 min) Rated short-time thermal current(Ith) 60In Rated dynamic current, (Idyn) 2.5Ith Rated voltage,(Um) 0.72Kv AC. Continuous overload,(Id) 1.2In Operating temperature -10C~50C Housing self-extinguishing class VO Safety factor... |
YUEQING YOMIN ELECTRIC CO., LTD
Zhejiang |
|
|
Brand Name:XG Model Number:LZZW-10 Place of Origin:XIAN,CHINA ...Current Transformer 1.rated insulation level: 12/42/75kV 2.rated frequency: 50/60Hz 3.burden power factor): COSØ=0.8 lagging 4.technical standard accords with):outdoor 5. technical standard according with:IEC60044-1:2003 2. Specification rated transformation ratio(A) Accuary classes combination rated output(VA) (ALF) (FS) short-time thermal current Ith(kA/S) rated dynamic current... |
Xi'an Xigao Electricenergy Group Co., Ltd.
Shanxi |
|
|
Brand Name:MacweyTEK Model Number:MDZK8-10 Place of Origin:China ...10 Toroidal Zero Sequence Transformer 70*110*H32 Inflatable Cabinet Waterproof Current Transformer Technical Parmeter Rated insulation level 12/42/75kV Power factor of load cOs φ=0.8(1agging) Rated secondary current 5Aor 10A Rated frequency 50 or 60Hz ... |
Ningbo Macwey Industrial Technology Co.,Ltd
|
|
|
Brand Name:Shareway Model Number:760805410 Place of Origin:Guangdong China ...current transformer Power Factor Correction Chokes Characteristics High efficiency Good EMC behavior Height as low as 13.1 mm Small footprint Suitable for mains voltage Isolation voltage of 1.5 kV AC Operating temperature: -40 °C to 125 °C Applications Active power factor... |
SHAREWAY TECHNOLOGY CO., LTD.
|
|
|
Place of Origin:Zhejiang, China Brand Name:Customized Model Number:MSQ-30B ...current transformer / MFO current transformer: 1.Model:MSQ-30,MSQ-30B,MSQ-30T,MSQ-40,MSQ-60,MSQ-85,MSQ-100,MSQ-125 2.Standard:IEC60044-1 3.Certificate:ISO9001:2000, ISO14001:1996,CE 4. Professory transformer manufacturer Specifications 1.Rated current:5/5A-6000/5A, 2.Secondary current :5A.1A 3.Rated voltage:0.72kV 4.Rated frequency:50/60Hz 5.Class of accuracy:0.5~1.0 6. Rated... |
YUEQING RENHE ELECTRIC CO., LTD.
|
|
|
Model Number:MCT10 Place of Origin:China Brand Name:CHIPSEN ... signal detection, energy monitoring, and overload protection in modern power systems. Built with premium magnetic core materials and a compact form factor, the MCT10 delivers reliable current measurement, low phase error, and |
Dongguan Chipsen Electronics Technology Co., Ltd.
Guangdong |
|
|
Place of Origin:China Brand Name:CTWELL Model Number:Miniature Lead Type Current Transformer ... type, customizable per customer requirements · Primary rated current: 1A-800A · Secondary rated current: 1mA-200mA · Accuracy: 0.1-2.0 Class Application: Widely used in motor overload protection and other overcurrent protection areas. FAQ Q: Are you |
HUBEI CTWELL Electronics Co.,Ltd.
Hubei |
|
|
Brand Name:RISING Model Number:RSHL-200A Place of Origin:China ...Transformer Testing Equipment High Accuracy CT/PT Standard Current Transformer Product Description The device can test transformer with accuracy level lower than two or two less level than this device. Technical Parameters Working temperature: -5℃~+40℃ Humidity: <80 Capacity: 5VA Power factor: COSφ=0.8-1 Allow long-term work at rated current and straight-through at above 150A Weight: <20KG Standard current... |
Wuhan Rising Electric Co., Ltd.
Hubei |
|
|
Place of Origin:China Brand Name:Yomin Model Number:CYR ...Current Transformer With Ring Core Current CYR current transformer adopts high quanlity PC materials,full-enclosed construction,round hole can pass busbar,be used for controlling,protection,measuring functions. P1,P2 primary terminals,S1,S2 secondary terminals. P1&S1 same as P2,S2 (Subtractive polarity). 1. Rated primary current 5-3000A rated secondary current 5A,1A 2. Rated voltage(KV) AC 660V 3. Rated... |
Yueqing Yomin Electric Co., Ltd
|
|
|
Place of Origin:China Brand Name:OEM Model Number:CA45/14 ...-5 ·High Voltage Test: 4KVeff,50Hz,1Min ·Weight: 200-250gr Rated Current(A) Primary/Secondary 30/5A 40/5A 50/5A 60/5A 75/5A 80/5A 100/5A Accuracy Class 3 1.0 1.0 1.0 1.0 Rated Burden(VA) 1 1.5 2.5 2.5 2.5 Outline Drawing Of |
OUTER ELECTRONIC TECHNOLOGY (HK) LIMITED
Guangdong |
|
|
Brand Name:HEMEI Model Number:HM-CTC1535 Place of Origin:China Split core current transformer clamp on type clamp-type leakage current sensor, also known as clamp-type current transformer, is suitable for AC current, leakage current, higher harmonic current, phase, energy, power, power factor and other detection. ... |
Hefei Hemei Electronics Technology Co., Ltd
Anhui |
|
|
Brand Name:GFUVE Model Number:LZCK-55 Place of Origin:China ...Current Transformer LZCK-55 Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13 Accuracy Class 0.5S, 0.5%, 1%, 3% Range of primary rated current 100-1000A Range of Rated load ≤10VA Rated frequency 50/60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
|
|
Brand Name:GENY Model Number:YCCTR-9901 Place of Origin:China ... 35kv / 600A Current Transformer Description: The YCCTR-9901 High-Voltage Current Transformer Turn-Ratio Test Set is meticulously crafted for precise on-line evaluation of turn ratios in current transformers rated at up to 10kV. This innovative system |
Guangzhou GENY Electric Co., Ltd
|
|
|
Model Number:CT-0800-F30 ...Current Transformers Littelfuse offers a wide array of instrument-rated current transformers in 1-3 inch diameter openings. These transformers are designed for instrumentation and metering applications.Product Attributes Brand: Littelfuse Voltage Class: 600V BIL Rating... |
Changsha Purple Horn E-Commerce Co., Ltd.
Hunan |
|
|
Brand Name:Purple Horn Place of Origin:China Model Number:KCT80 ... Zero Phase Current Transformer 0.3A 3kV for Relay Protection Description: This type of current transformer is used indoor to measure the current and energy and perform relaying protection in AC circuit rated voltage up to 660V and rated frequency 50/60hz... |
Hefei Purple Horn E-Commerce Co., Ltd.
Anhui |
|
|
Brand Name:HAOMAI Model Number:CTP-200P Place of Origin:China ...Current Transformer Test Set Model: CTP-200P The Portable Current Transformer Test Set CTP-200P is designed to automatically measure the related parameters of current transformer(CT), such as excitation characteristic, turns ratio, polarity, winding resistance, saturated and unsaturated inductivity, remanence flux percentage, accuracy limiting factor(ALF) or instrument security factor... |
HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD
|