| Sign In | Join Free | My futurenowinc.com |
|
| Categories | Walk In Environmental Test Chamber |
|---|---|
| Brand Name: | Sinuo |
| Model Number: | SN886-3.38m³ |
| Certification: | Calibration Certificate (Cost Additional) |
| Place of Origin: | China |
| MOQ: | 1 |
| Payment Terms: | T/T |
| Supply Ability: | 10 Sets Per Month |
| Delivery Time: | 30 Days |
| Packaging Details: | Export packing |
| Effective volume: | 3.38m³ |
| Temperature range: | -40~+100℃ |
| Humidity fluctuation: | ±3.0%RH |
| Humidity range: | 20%〜98%RH |
| Heating rate: | About 3℃/min |
| Cooling rate: | Average 1℃/min |
| External dimensions Approx.: | 1600 mm*1900 mm*2450 mm(W*D*H) |
| Inner box dimensions: | 1300 mm*1300 mm*2000mm(W*D*H) |
| Company Info. |
| Sinuo Testing Equipment Co. , Limited |
| Verified Supplier |
| View Contact Details |
| Product List |
Large Climate Test Chamber Walk-in Test Chamber for Electronics
Complied Standards & Clauses
Applied Standard:
IEC60068-2-1:2007 Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT
IEC60068-2-2:2007 Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT
IEC60068-2-78:2001 Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT
IEC60068-2-22:2005 Environmental Testing Part 2-22: Tests Test N: Change of temperature, IDT
Product Overview
Features:
Technical Parameters
| Inner box volume | 3.38m³ |
| Temperature range | -40~+100℃ |
| Temperature uniformity | ±2.0℃ (In steady state) |
| Temperature fluctuation | ±0.5℃ (In steady state) |
| Temperature deviation | ±2.0℃ (In steady state) |
| Heating rate | About 3℃/min (average rate over the whole process under no load) |
| Cooling rate | Average 1℃/min (average rate over the whole process under no load) |
| Humidity range | 20%〜98%RH |
| Humidity fluctuation | ±3.0%RH (at constant state) |
| Humidity deviation | +2.0%RH~-3%RH (>75%RH); ±5.0%RH (≤75%RH) (at constant state) |
| Cooling method | Water-cooled type |
| Power supply voltage | 380V±10% (three-phase five-wire); 50Hz±10% |
| Working principle | Forced ventilation internal circulation, balanced temperature and humidity control method |
| Air circulation device | Extended shaft centrifugal fan, long shaft external motor drive |
| Air heating method | Use special spiral nickel-chromium alloy resistive electric heater with large heat dissipation area; PID+SSR drive control; |
| Water cooling method | Water-cooled heat exchanger |
| Dehumidification method | Refrigeration light tube surface dehumidification |
| Heating method | Nickel-chromium alloy electric heating wire heating, PID adjustment, actuator: solid-state relay |
Details


|